Actuators
These are electro pneumatic distributors, designed for handling equipment and machinery, which operate for long periods in any type of situation.
The experience gained over years of installation on machines operating in extremely difficult atmospheric and environmental conditions (vibrations, humidity and air salinity, high or low temperatures, dust, etc.) led to the development of technical solutions that guarantee durability over time and reliability. The actuators are integrated into a CAN network. The power supply complies with the automotive standard (9-36 VDC).
Here are all of our models

AL35R15
The AL35R15 electro pneumatic distributor is suitable for perform the pneumatic distribution on moving machinery and equipment.
It’s available in 5 different versions: 4, 5, 6, 7, and 8 elements. It can be implemented as SLAVE in a CAN network.
Built with high quality components, the distributor is suitable to resists to vibrations and water, for use on machines that operate in harsh work environments and for applications where flexibility and reliability of the automation system are required.
POWER SUPPLY: ELECTRONIC BOARD: 9–36 VDC / CURRENT CONSUMPTION 50 mA @24 VDC (STAND BY MODE) – ELECTROVALVES: 12VDCOR 24VDC
GENERAL AIR SUPPLY: 8 BAR
OUTPUT: UP TO 16 E.V.(SEE THE PURCHASE CODES «E.V. OUT» FOR OPTIONS)
AIR FLOW RATE: 30Nl/min(@ 6 bar Δp 1 bar, FOR SIGLE E.V.)
LED: N.1 STATUS LED
CAN BUS (1 PORT): 2.0B COMPLIANT -(11, 29 BIT) -ISO 11898 -UP TO 1MBIT/S
CAN BUS PROTOCOLS: CAN OPEN (CIA DS401 DEVICE PROFILE FOR GENERIC I/O MODULE, WITH DS306 EDS FILE)ON REQUEST: SAE J1939
CONNECTIONS:
ELECTRICAL: AMP SUPERSEAL 4 PINFPM
PNEUMATIC: SWIVEL PNEUMATIC CONNECTION WITH QUICK COUPLING FOR PIPES Ø 6 mm
ON REQUEST: Ø 4 mm
CASE: BASE: ANODIZED ALUMINUM – CARTER: PA66 25%FV V0
WORKING TEMPERATURE: -40°C +80°C
SLAVE USAGE | EDS FILE |
PROGRAMMING | FIRMWARE UPLOAD BY CAN BUS WITH BOOTLOADER |
IP GRADE | CASE: IP68 PNEUMATIC FITTINGS: IP65 |
ELECTROMAGNETIC EMISSIONS | EN 61000-6-4// EN 55011 (RF RADIATE) |
ELECTROMAGNETIC IMMUNITY | EN 61000-6-2// EN 61000-4-2/3/4/6 |
MTTFd | 407 YEARS CALCULATED ACCORDING TO THE IEC61709 (SIEMENS SN29500), ENVIRONMENTAL FACTORS 3K7 (IEC60721). E.V. CYCLE TIME: 60 s (FOR 8 h/day, 300 day/year) |
ELECTRONIC PERFORANCE AND SAFETY LEVEL |
PLc – SIL1 (SINGLE-CHANNEL INTERNAL SCHEME) |
IN ACCORDANCE WITH THE EN50498 THE DEVICE MEETS THE TECHNICAL SPECIFIC REQUIREMENTS OF 2004-104 DIRECTIVE (AUTOMOTIVE). THE DEVICE IS EMC 2004/108 COMPLIANT |